{"id":103,"date":"2024-03-08T16:12:14","date_gmt":"2024-03-08T16:12:14","guid":{"rendered":"http:\/\/localhost\/wordpress\/?page_id=103"},"modified":"2024-03-13T17:55:53","modified_gmt":"2024-03-13T17:55:53","slug":"revize","status":"publish","type":"page","link":"https:\/\/www.lygre.cz\/?page_id=103","title":{"rendered":"REVIZE EL. ZA\u0158\u00cdZEN\u00cd A HROMOSVOD\u016e"},"content":{"rendered":"\n<h3 class=\"wp-block-heading\"><strong>Pro\u010d jsou revize nutn\u00e9?<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u2022 Dle platn\u00fdch z\u00e1kon\u016f a na\u0159\u00edzen\u00ed, je ka\u017ed\u00fd provozovatel elektrick\u00e9ho za\u0159\u00edzen\u00ed (podnikatel) povinen          zajistit revize elektrick\u00fdch za\u0159\u00edzen\u00ed dle \u010cSN 33 1500, revize elektrick\u00e9ho ru\u010dn\u00edho n\u00e1\u0159ad\u00ed dle \u010cSN 33 1600 a revize elektrick\u00fdch spot\u0159ebi\u010d\u016f dle \u010cSN 33 1610<br>\u2022 Zjist\u00ed, je-li va\u0161e elektroinstalace v po\u0159\u00e1dku a bez z\u00e1vad.<br>\u2022 Ochr\u00e1n\u00ed v\u00e1s p\u0159ed p\u0159\u00edpadn\u00fdm \u00farazem elektrick\u00fdm proudem<br>\u2022 Sn\u00ed\u017e\u00ed riziko nebezpe\u010dn\u00ed po\u017e\u00e1r\u016f<br>\u2022 Revize vy\u017eaduj\u00ed platn\u00e9 z\u00e1kony, na\u0159\u00edzen\u00ed vl\u00e1dy a vyhl\u00e1\u0161ky<br>\u2022 V p\u0159\u00edpad\u011b po\u017e\u00e1ru, \u00farazu el. proudem poji\u0161\u0165ovna nevyplat\u00ed pojistnou \u010d\u00e1stku nebo pln\u011bn\u00ed v\u00fdrazn\u011b zkr\u00e1t\u00ed<br>\u2022 Proto\u017ee V\u00e1m m\u016f\u017ee kontroln\u00ed org\u00e1n ( Inspektor\u00e1t pr\u00e1ce ) ud\u011blit finan\u010dn\u00ed pokuty a\u017e do v\u00fd\u0161e 2.000.000,- K\u010d, dle z\u00e1kona \u010d.: 251\/2005 Sb<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Revize elektrick\u00fdch za\u0159\u00edzen\u00ed<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u2022 Revize elektrick\u00fdch za\u0159\u00edzen\u00ed dle \u010cSN 33 1500 a \u010cSN 33 2000-6 Pro revize elektrick\u00fdch za\u0159\u00edzen\u00ed ( el. instalace ) plat\u00ed \u010cSN 33 1500 a \u010cSN 33 2000-6.<br>\u2022 Revize rozli\u0161ujeme na V\u00ddCHOZ\u00cd a PRAVIDELN\u00c9.<br>\u2022 V\u00ddCHOZ\u00cd revize se prov\u00e1d\u011bj\u00ed p\u0159ed uveden\u00edm nov\u00e9ho za\u0159\u00edzen\u00ed do provozu.<br>\u2022 PRAVIDELN\u00c9 revize se prov\u00e1d\u011bj\u00ed b\u011bhem provozu elektrick\u00e9ho za\u0159\u00edzen\u00ed ve stanoven\u00fdch lh\u016ft\u00e1ch.<br>\u2022 LH\u016eTY reviz\u00ed jsou r\u016fzn\u00e9 a pohybuj\u00ed se od jednoho roku do 5 let, v z\u00e1vislosti na um\u00edst\u011bn\u00ed el. za\u0159\u00edzen\u00ed, povaze skladovan\u00fdch \u010di zpracov\u00e1van\u00fdch l\u00e1tek apod. Pro b\u011b\u017en\u00e9 kancel\u00e1\u0159sk\u00e9 budovy, restaurace, d\u00edlny apod. plat\u00ed lh\u016fta 5 let.<br>\u2022 CENY:Ceny reviz\u00ed el. instalac\u00ed se pohybuj\u00ed v z\u00e1vislosti na rozsahu revidovan\u00e9ho za\u0159\u00edzen\u00ed a podm\u00ednk\u00e1ch revize.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.lygre.cz\/?page_id=328\">Popt\u00e1vka revize<\/a><\/div>\n<\/div>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Revize hromosvod\u016f dle \u010cSN 34 1390 resp. EN 62305-1 &#8211; 4<\/strong><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u2022 Zm\u011bnila se po\u017eadavky na po\u017eadavky syst\u00e9mu ochrany p\u0159ed bleskem. Proto je nutn\u00e9 si nechat prov\u011b\u0159it v\u00e1\u0161 hromosvod. V p\u0159\u00edpad\u011b z\u00e1sahu do va\u0161eho objektu a p\u0159\u00edpadn\u00fdm \u0161kod\u00e1m, by v\u00e1m poji\u0161\u0165ovna nemusela vyplatit zp\u016fsoben\u00e9 \u0161kody v pln\u00e9 v\u00fd\u0161i. Nechte si rad\u011bji hromosvod prov\u011b\u0159it!<br>\u2022 Je nutn\u00e9 vyhodnocen\u00ed pot\u0159eby ochrany p\u0159ed bleskem metodou ocen\u011bn\u00ed rizika<br>\u2022 Nov\u00e9 jsou \u010dty\u0159i hladiny ochrany staveb p\u0159ed bleskem<br>\u2022 D\u00e1le jsou zde po\u017eadavky na ochranu el. za\u0159\u00edzen\u00ed a elektron. za\u0159\u00edzen\u00ed ve stavb\u00e1ch proti p\u0159\u00edm\u00edm \u00fa\u010dinku\u016fm bleskov\u00e9ho proudu i proti \u00fa\u010dink\u016fm magnetick\u00fdch pol\u00ed vyvolan\u00fdch bleskem pomoc\u00ed pospojov\u00e1n\u00ed, veden\u00ed tras, megnetick\u00fdch st\u00edn\u011bn\u00ed a p\u0159ep\u011b\u0165ov\u00fdch ochran\u00fdch za\u0159\u00edzen\u00ed.<br>\u2022 Revize hromosvod\u016f tak\u00e9 rozli\u0161ujeme na v\u00fdchoz\u00ed a pravideln\u00e9<br>\u2022 Revize hromosvodu bytov\u00e9 a kancel\u00e1\u0159sk\u00e9 domy-revize hromosvodu hotely a ubytovny<br>\u2022 Revize hromosvod\u016f \u0161koly-revize hromosvodu \u0161kolky-revize hromosvodu jesle (ochrana p\u0159ed bleskem)<br>\u2022 Revize rodinn\u00fdch dom\u016f,rekrea\u010dn\u00edch chat, chalup, anten\u00edch syst\u00e9mu apod.<br>\u2022 Hromosvod mus\u00ed m\u00edt dle vyhl\u00e1\u0161ky instalov\u00e1ny zejm\u00e9na ty budovy, kde opravdu existuje re\u00e1ln\u00e9 nebezpe\u010d\u00ed a kde by mohl blesk ohrozit \u017eivot a zdrav\u00ed osob nebo zp\u016fsobit zna\u010dn\u00e9 majetkov\u00e9 \u0161kody. Jedn\u00e1 se nap\u0159\u00edklad o \u010din\u017eovn\u00ed domy, \u0161kolsk\u00e9 \u010di zdravotnick\u00e9 budovy, pr\u016fmyslov\u00e9 objekty, stavby p\u0159evy\u0161uj\u00edc\u00ed okol\u00ed, postaven\u00e9 na n\u00e1vr\u0161\u00ed apod. Z\u00e1le\u017e\u00ed na odpov\u011bdnosti ka\u017ed\u00e9ho z n\u00e1s, zda na sv\u00e9m rodinn\u00e9m dom\u011b, chat\u011b \u010di chalup\u011b nech\u00e1 nainstalovat hromosvodn\u00ed soustavu.<br>\u2022 Samotn\u00fd hromosvod je v\u011bt\u0161inou konstruov\u00e1n p\u0159edev\u0161\u00edm na ochranu budovy p\u0159ed po\u0161kozen\u00edm bleskem a p\u0159ed vznikem po\u017e\u00e1ru od blesku. Existuje i vnit\u0159n\u00ed slo\u017eka ochrany proti atmosf\u00e9rick\u00e9 elekt\u0159in\u011b &#8211; bezpe\u010dnost V\u00e1m zajist\u00ed revizi hromosvodu a revize elektroinstalace<br>\u2022 Prov\u00e1d\u00edme vyzu\u00e1ln\u00ed revize, m\u011b\u0159en\u00ed pospojov\u00e1n\u00ed, m\u011b\u0159en\u00ed odporu zemni\u010de a spoj\u016f<br>\u2022 Prov\u00e1d\u00edme revize po \u00faderu bleskem, kde je nezbytn\u00e9 revizi ud\u011blat<\/p>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.lygre.cz\/?page_id=328\">Popt\u00e1vka revize hromosvodu<\/a><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Pro\u010d jsou revize nutn\u00e9? \u2022 Dle platn\u00fdch z\u00e1kon\u016f a na\u0159\u00edzen\u00ed, je ka\u017ed\u00fd provozovatel elektrick\u00e9ho za\u0159\u00edzen\u00ed (podnikatel) povinen zajistit revize elektrick\u00fdch za\u0159\u00edzen\u00ed dle \u010cSN 33 1500, revize elektrick\u00e9ho ru\u010dn\u00edho n\u00e1\u0159ad\u00ed dle \u010cSN 33 1600 a revize elektrick\u00fdch spot\u0159ebi\u010d\u016f dle \u010cSN 33 1610\u2022 Zjist\u00ed, je-li va\u0161e elektroinstalace v po\u0159\u00e1dku a bez z\u00e1vad.\u2022 Ochr\u00e1n\u00ed v\u00e1s p\u0159ed p\u0159\u00edpadn\u00fdm \u00farazem [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"wp-custom-template-revize","meta":{"footnotes":""},"class_list":["post-103","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/www.lygre.cz\/index.php?rest_route=\/wp\/v2\/pages\/103","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.lygre.cz\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.lygre.cz\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.lygre.cz\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.lygre.cz\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=103"}],"version-history":[{"count":1,"href":"https:\/\/www.lygre.cz\/index.php?rest_route=\/wp\/v2\/pages\/103\/revisions"}],"predecessor-version":[{"id":482,"href":"https:\/\/www.lygre.cz\/index.php?rest_route=\/wp\/v2\/pages\/103\/revisions\/482"}],"wp:attachment":[{"href":"https:\/\/www.lygre.cz\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=103"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}